﻿{"id":31,"date":"2014-09-08T11:19:59","date_gmt":"2014-09-08T09:19:59","guid":{"rendered":"http:\/\/blazecut.com\/?page_id=31"},"modified":"2015-02-18T16:02:22","modified_gmt":"2015-02-18T14:02:22","slug":"description","status":"publish","type":"page","link":"https:\/\/blazecut.com\/oldsite\/local-application\/description\/","title":{"rendered":"Description"},"content":{"rendered":"<p><img style=\"float:right; padding-left: 20px;width: 158px;\" src=\"..\/..\/wp-content\/themes\/twentytwelve\/images\/local_desc_photo.png\" alt=\"\"><\/p>\n<div style=\"text-align:justify;\">Engine compartments of vehicles and machines, server rooms, electrical cabinets, power generators and similar devices are closed spaces with increased risk of fire and out of sight. In case of fire such combination may have devastating consequences such as damaging property, interrupting business or in the worst case scenario losing lives.<\/p>\n<p>Local application systems from the BlazeCut \u201cC\u201d Series product line provide effective fire protection of such larger enclosures. Automatic operation, fast detection and effectiveness are the most important elements of the \u201cC\u201d Series systems.<\/p>\n<p>The system operates automatically independent of any power supply, which is a key advantage, as the system is able to effectively operate and suppress fire in spaces even when people are not present. The system operation is based on a pneumatic detection tubing technology which is sensitive to high temperatures. The detection tube is a \u201cheart\u201d of each BlazeCut \u201cC\u201d Series System providing detection function and in some types of the systems also release of agent function (DLP System). Pneumatic detection\/activation operates solely on physical principles.<\/p>\n<p>Selected ILP Systems include an electric solenoid for electric actuation using smoke and heat detectors for detection and connection to fire control panel with GSM module.\n<\/p><\/div>\n<div style=\"display:inline-block;vertical-align: top;width: 400px;text-align: justify;\">\nDepending on the type of application the systems are supplied in various modifications such as:<\/p>\n<ul>\n<li>Type of valve: DLP or ILP<\/li>\n<li>Type of agent: Novec 1230, HFC-227ea, HFC-236fa, foam, powder<\/li>\n<li>Volume of cylinder: different volumes depending on type of extinguishing agent<\/li>\n<li>Dimensions of detection tube<\/li>\n<li>Wide range of components and installation material: distribution tubing, fittings, connectors, brackets<\/li>\n<li>Various optional components: pressure switch, control units, signaling devices, actuators, detectors, end of line devices<\/li>\n<\/ul>\n<\/div>\n<div style=\"display:inline-block;vertical-align: top;width: 240;text-align: justify;margin: 0 40px;\">\nTypical vehicle and machine applications:<\/p>\n<ul>\n<li>Buses and coaches<\/li>\n<li>Trucks and vans<\/li>\n<li>Construction vehicles<\/li>\n<li>Agricultural vehicles<\/li>\n<li>Mining machines<\/li>\n<li>Forestry machines<\/li>\n<li>Special army and police vehicles<\/li>\n<li>Marine<\/li>\n<li>Other<\/li>\n<\/ul>\n<\/div>\n<div style=\"display:inline-block;vertical-align: top;width: 190px;text-align: justify;\">\nTypical indoor applications:<\/p>\n<ul>\n<li>CNC machines<\/li>\n<li>Server racks<\/li>\n<li>Electrical cabinets<\/li>\n<li>Kitchens<\/li>\n<li>Fume cabinets<\/li>\n<li>Power generators<\/li>\n<li>Telecom tower shelters<\/li>\n<li>Ventilation devices<\/li>\n<li>Elevator engines<\/li>\n<li>Other<\/li>\n<\/ul>\n<\/div>\n<div id=\"description-icons\">\n<div class=\"desc-item\">\n<div class=\"desc-icon\">\n\t\t\t<img src=\"..\/..\/wp-content\/themes\/twentytwelve\/images\/description\/automatic.png\" alt=\"\" \/>\n\t\t<\/div>\n<div class=\"desc-heading\">Automatic<\/div>\n<\/p><\/div>\n<div class=\"desc-item\">\n<div class=\"desc-icon\">\n\t\t\t<img src=\"..\/..\/wp-content\/themes\/twentytwelve\/images\/description\/fast-detection.png\" alt=\"\" \/>\n\t\t<\/div>\n<div class=\"desc-heading\">Fast detection<\/div>\n<\/p><\/div>\n<div class=\"desc-item\">\n<div class=\"desc-icon\">\n\t\t\t<img src=\"..\/..\/wp-content\/themes\/twentytwelve\/images\/description\/effectiveness.png\" alt=\"\" \/>\n\t\t<\/div>\n<div class=\"desc-heading\">Effectiveness<\/div>\n<\/p><\/div>\n<div class=\"desc-item\">\n<div class=\"desc-icon\">\n\t\t\t<img src=\"..\/..\/wp-content\/themes\/twentytwelve\/images\/description\/harmless.png\" alt=\"\" \/>\n\t\t<\/div>\n<div class=\"desc-heading\">Harmless<\/div>\n<\/p><\/div>\n<div class=\"desc-item\">\n<div class=\"desc-icon\">\n\t\t\t<img src=\"..\/..\/wp-content\/themes\/twentytwelve\/images\/description\/easy-to-install.png\" alt=\"\" \/>\n\t\t<\/div>\n<div class=\"desc-heading\">Easy installation<\/div>\n<\/p><\/div>\n<div class=\"desc-item\">\n<div class=\"desc-icon\">\n\t\t\t<img src=\"..\/..\/wp-content\/themes\/twentytwelve\/images\/description\/maintenance-free.png\" alt=\"\" \/>\n\t\t<\/div>\n<div class=\"desc-heading\">Simple maintenance<\/div>\n<\/p><\/div>\n<div class=\"desc-item\">\n<div class=\"desc-icon\">\n\t\t\t<img src=\"..\/..\/wp-content\/themes\/twentytwelve\/images\/description\/long-durability.png\" alt=\"\" \/>\n\t\t<\/div>\n<div class=\"desc-heading\">Long lifespan<\/div>\n<\/p><\/div>\n<div class=\"desc-item\">\n<div class=\"desc-icon\">\n\t\t\t<img src=\"..\/..\/wp-content\/themes\/twentytwelve\/images\/description\/cost-effective.png\" alt=\"\" \/>\n\t\t<\/div>\n<div class=\"desc-heading\">Cost-effective<\/div>\n<\/p><\/div>\n<div class=\"desc-item\">\n<div class=\"desc-icon\">\n\t\t\t<img src=\"..\/..\/wp-content\/themes\/twentytwelve\/images\/description\/universal-use.png\" alt=\"\" \/>\n\t\t<\/div>\n<div class=\"desc-heading\">Universal use<\/div>\n<\/p><\/div>\n<div class=\"desc-item\">\n<div class=\"desc-icon\">\n\t\t\t<img src=\"..\/..\/wp-content\/themes\/twentytwelve\/images\/description\/safe-for-people.png\" alt=\"\" \/>\n\t\t<\/div>\n<div class=\"desc-heading\">Safe for people<\/div>\n<\/p><\/div>\n<div class=\"desc-item\">\n<div class=\"desc-icon\">\n\t\t\t<img src=\"..\/..\/wp-content\/themes\/twentytwelve\/images\/description\/independent.png\" alt=\"\" \/>\n\t\t<\/div>\n<div class=\"desc-heading\">Independent of power supply<\/div>\n<\/p><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Engine compartments of vehicles and machines, server rooms, electrical cabinets, power generators and similar devices are closed spaces with increased risk of fire and out of sight. In case of fire such combination may have devastating consequences such as damaging property, interrupting business or in the worst case scenario losing lives. Local application systems from [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":21,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/blazecut.com\/oldsite\/wp-json\/wp\/v2\/pages\/31"}],"collection":[{"href":"https:\/\/blazecut.com\/oldsite\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/blazecut.com\/oldsite\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/blazecut.com\/oldsite\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/blazecut.com\/oldsite\/wp-json\/wp\/v2\/comments?post=31"}],"version-history":[{"count":39,"href":"https:\/\/blazecut.com\/oldsite\/wp-json\/wp\/v2\/pages\/31\/revisions"}],"predecessor-version":[{"id":424,"href":"https:\/\/blazecut.com\/oldsite\/wp-json\/wp\/v2\/pages\/31\/revisions\/424"}],"up":[{"embeddable":true,"href":"https:\/\/blazecut.com\/oldsite\/wp-json\/wp\/v2\/pages\/21"}],"wp:attachment":[{"href":"https:\/\/blazecut.com\/oldsite\/wp-json\/wp\/v2\/media?parent=31"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}